CLIMATIC CHAMBERS
Code C314: Designed for all the research and control laboratories where known cold and/or hot temperatures with controlled humidity values are required for any type for freeze /thaw tests, accelerated curing tests, hot and cold tests in general. Used also to check the behaviour of aggregates during freeze and thaw cycle tests according to: EN 1367/1 -ASTM C671 BS 812:124 -CNR N ° 80 UNI 8520 STANDARDS
Temperature range:-20 °C +60 °C.Accur acy ± 0,5 °C.
Humidity range:10 ÷90%,dew point limit +2 °C.
Inside and outside frame:totally in stainless steel
Digital display of actual and preset temperature
Internal ventilation:forced circulation.
Inside useful capacity: 520 litres.
Inside dimensions: 620x630x1390 mm
Overall dimensions: 730x860x2090 mm
Complete with 3 adjustable shelves, RS 485 interface
Power supply: 220-240 V 1ph 50 Hz 1000 W
Weight: 150 kg
Code C315: Climatic chamber, same as mod. C314 but having:
Inside useful capacity: 1200 litres
Double entrance door
Inside dimensions: 1240x730x1390 mm
Overall dimensions: 1460x860x2090 mm
Complete with 4 adjustable shelves. Weight: 230 kg
Code C314-01: Climatic controlled cabinet same to C314, but equipped also of microprocessor temperature programmer for the automatic execution of the set cycles.
Code C313: Climatic controlled cabinet 700 litres cap.
- Temperature: -25 to +70°C, stability 0,1°C
- Humidity: 10 to 90%, accuracy ± 1%
- Dew point: +2°C
Designed for all the research and control laboratories to perform: cold and/or hot temperature measurement at controlled humidity conditions, any kind of freezing/thawing tests, accelerated curing tests.
Used to cure concrete (EN 12390-2), and cement specimens (EN 196-1), to analyze the behavior of aggregates to freezing and thawing tests (EN 1367-1).
Internal capacity: 700 litres.
Internal and external frame made of stainless steel AISI 304.
Polyurethane insulation, 75 mm thick.
Internal ventilation.
Reversible doors with autoclosing hinges and opening lock beyond 90°, rechangeable magnetic gaskets, rounded corners, inside doors in lexan.
Shelves can be taken off and adjustable in height; adjustable feet.
Temperature sensor can be placed at every point of the climatic cabinet; it can also be placed within the specimen.
The cabinet is supplied with a “decalcification filter”; it works with demineralized or softened waters, or aqueduct waters with CaCO3 hardness from 0 to 400 ppm, assuring an excellent functioning along the time.
Complete with microprocessor one cycle programmer and 20 temperature segments.
Real-time visualization of the internal temperature and of the set temperature on the digital display.
Audiovisual alarm of minimum and maximum temperature (audio signal can be switched off).
Password to access the cabinet commands.
Security device Class 3.1 (DIN 12880) with automatic activation of two further security thermoregulators.
Supplied complete with 3 adjustable shelves.
Inside dimensions: 600x670x1350 mm
Overall dimensions: 720x800x2070 mm
Power supply: 230V 1ph 50Hz 1800W
Weight approx.: 180 kg
Code C313-01: Climatic cabinet 1500 litres cap.
Same as C313 model, but with an internal capacity of 1500 litres.
Supplied complete with 6 adjustable shelves.
Inside dimensions: 1320x670x1350 mm
Overall dimensions: 1440x800x2070 mm
Weight: about 360 kg
Code C315-05: Climatic controlled cabinet. Same to C315, but equipped also of microprocessor temperature programmer for the automatic test cycl